S.M.A.R.T. Service Screen
1 minute read.
Last Modified 2022-09-16 15:29 -0400The Services > S.M.A.R.T. screen displays settings to configure when S.M.A.R.T. tests run and when to trigger alert warnings and send emails.
Name | Description |
---|---|
Check Interval | Enter the time in minutes for smartd to wake up and check if any tests are configured to run. |
Power Mode | Select the power mode from the dropdown list. Options are Never, Sleep, Standby or Idle. S.M.A.R.T. only tests when the Power Mode is Never. |
Difference | Enter a number of degrees in Celsius. S.M.A.R.T. reports if a drive temperature changes by N degrees Celsius since the last report. |
Informational | Enter a threshold temperature in Celsius. S.M.A.R.T. sends a message with a LOG_INFO log level if the temperature is above the threshold. |
Critical | Enter a threshold temperature in Celsius. S.M.A.R.T. sends a message with a LOG_CRIT log level and send an email if the temperature is above the threshold. |